A R T PRO MPA SPECIFICATIONS
Dimensions: 3.50Ó H x 19Ó W x 6.5Ó D
Input Connections: XLR (balanced), 1/4Ó unbal.
Output Connections: XLR (balanced), 1/4Ó unbal.
Input Impedance: XLR, 1/4Ó 1.67k ohms, 840K ohms
Output Impedance: XLR, 1/4Ó 600 ohms, 300 ohms
Maximum Input Level: XLR +17dBu
Maximum Input Level: 1/4Ó +20dBu
Maximum Output Level: XLR +28dBu
Maximum Output Level: 1/4Ó +22dBu
CMRR >90dB (typical @ 1kHz)
Frequency Response 20Hz to 40kHz (+0, -1dB)
Dynamic Range >100dB (20Hz to 20kHz)
Total Harmonic Distortion(THD) <0.1% (typical)
Maximum Gain: XLR to XLR >72dB
Equivalent Input Noise (EIN)
XLR to XLR (shorted input) >-124dBu unweighted
>-133dBu (ÔAÕ weighted)
Power Requirements: 100-125VAC, 25W - (USA)
Internal fuse. Other power require
ments configured for country of desti
nation.
A R T retains a policy of constant product improvement. A R T reserves the right
to make changes in design or make additions to or improvements upon this
product without any obligation to install the same on products previously manu-
factured. Therefore, specifications are subject to change without notice.
Designed and manufactured in the United States of America.
Applied Research and Technology, Inc. (716) 436-2720 (Phone)
215 Tremont Street (716) 436-3942 (FAX)
Rochester, NY 14608 USA
WEÕRE ON-LINE!
For Product information, questions, applications, tips, answers and general dis-
cussion with A R T employees look for
A R T on the Internet..
Look for the A R T folder on America Online in Craig AndertonÕs Stage Studio
and Sound (keyword ÒSSSÓ) under the Manufacturer Supported Forums. Email
Look for the A R T supported area in the MIDI Forum B area on CompuServe
(Go MIDI). CompuServe address: 76702,3700. Email us at [email protected]
puserve.com
Check out our Web Page at: http://www.artroch.com
©1996 Applied Research and Technology, Inc.
1) Be sure the unit is the cause of the problem. Check to make
sure the unit has power supplied, all cables are connected cor-
rectly, and the cables themselves are in working condition.
2) If you find the unit to be at fault, write down a description of
the problem, including how and when the problem occurs.
3) Call the factory for a Return Authorization (RA) number.
4) Pack the unit in its original carton or reasonable substitute.
The packing box is not recommended for a shipping carton. Put
the packaged unit in another box for shipping. Print the RA
number clearly under the address.
5) Include with your unit: a return shipping address (we cannot
ship to a P.O. Box), a copy of your purchase receipt, a daytime
phone number and the description of the problem.
6) Ship the unit to:
Applied Research and Technology, Inc.
215 Tremont Street
Rochester, NY 14608
Atten: Repair Department
R.A.# _______________
7) Contact our Customer Service department at 716/436-2720
for your Return Authorization number or questions regarding
your repair. Customer Service hours are Monday through Friday